Nuclear Medicine and Biology
Volume 36, Issue 4 , Pages 403-409 , May 2009

Development of microwave-based automated nucleophilic [18F]fluorination system and its application to the production of [18F]flumazenil

  • Katheryn S. Mandap

      Affiliations

    • Biomedical Imaging Research Center, University of Fukui, Fukui 910-1193, Japan
  • ,
  • Tatsuo Ido

      Affiliations

    • Biomedical Imaging Research Center, University of Fukui, Fukui 910-1193, Japan
    • Japan Radioisotope Association, Tokyo 113-8491, Japan
  • ,
  • Yasushi Kiyono

      Affiliations

    • Biomedical Imaging Research Center, University of Fukui, Fukui 910-1193, Japan
    • Corresponding Author InformationCorresponding author. Tel.: +81 776 61 8420; fax: +81 776 61 8170.
  • ,
  • Masato Kobayashi

      Affiliations

    • Biomedical Imaging Research Center, University of Fukui, Fukui 910-1193, Japan
  • ,
  • Talakad G. Lohith

      Affiliations

    • Biomedical Imaging Research Center, University of Fukui, Fukui 910-1193, Japan
  • ,
  • Tetsuya Mori

      Affiliations

    • Biomedical Imaging Research Center, University of Fukui, Fukui 910-1193, Japan
  • ,
  • Shingo Kasamatsu

      Affiliations

    • Biomedical Imaging Research Center, University of Fukui, Fukui 910-1193, Japan
  • ,
  • Takashi Kudo

      Affiliations

    • Biomedical Imaging Research Center, University of Fukui, Fukui 910-1193, Japan
  • ,
  • Hidehiko Okazawa

      Affiliations

    • Biomedical Imaging Research Center, University of Fukui, Fukui 910-1193, Japan
  • ,
  • Yasuhisa Fujibayashi

      Affiliations

    • Biomedical Imaging Research Center, University of Fukui, Fukui 910-1193, Japan

Received 24 December 2008 ,Revised 21 January 2009 ,Accepted 23 January 2009.

References 

  1. Stone-Elander S, Elander N. Fast chemistry in microwave fields: nucleophilic 18F-radiofluorinations of aromatic molecules. Appl Radiat Isot. 1993;44(5):889–893
  2. Elander N, Jones JR, Lu SY, Stone-Elander S. Microwave-enhanced radiochemistry. Chem Soc Rev. 2000;29:239–249
  3. Stone-Elander S, Elander N. Microwave applications in radiolabelling with short-lived positron emitting radionuclides. J Label Compd Radiopharm. 2002;45:715–746
  4. Taylor MD, Roberts AD, Nickles RJ. Improving the yield of 2-[18F]fluoro-2-deoxyglucose using a microwave cavity. Nucl Med Biol. 1996;23:605–609
  5. Hayes BL. Microwave synthesis (chemistry at the speed of light). North Carolina: CEM publishing; 2002;
  6. Pike VW, Halldin C, Crouzel C, Barré L, Nutt DJ, Osman S, et al. Radioligands for PET studies of central benzodiazepine receptors and PK (peripheral benzodiazepine) binding sites — current status. Nucl Med Biol. 1993;20:503–525
  7. Ryvlin P, Bouvard S, Le Bars D, De Lamérie G, Grégoire C, Kahane P, et al. Clinical utility of flumazenil-PET versus [18F]fluorodeoxyglucose-PET and MRI in refractory partial epilepsy. Brain. 1998;121:2067–2081
  8. Malizia AL, Cunningham VJ, Bell CJ, Liddle PF, Jones T, Nutt DJ. Decreased brain GABAA-benzodiazepine receptor binding in panic disorder. Arch Gen Psychiatry. 1998;55:715–720
  9. Holthoff VA, Koeppe RA, Frey KA, Penney JB, Markel DS, Kuhl DE, et al. Positron emission tomography measures of benzodiazepine receptors in Huntington’s disease. Ann Neurol. 1993;34(1):76–81
  10. Heiss WD, Grond M, Thiel A, Ghaemi M, Sobesky J, Rudolf J, et al. Permanent cortical damage detected by flumazenil positron emission tomography in acute stroke. Stroke. 1998;29(2):454–461
  11. Heiss WD, Kracht L, Grond M, Rudolf J, Bauer B, Wienhard K, et al. Early [11C]flumazenil/H2O positron emission tomography predicts irreversible ischemic cortical damage in stroke patients receiving acute thrombolytic therapy. Stroke. 2000;31(2):366–369
  12. Ryzhikov NN, Seneca N, Krasikova RN, Gomzina NA, Shchukin E, Fedorova OS, et al. Preparation of highly specific radioactivity [18F]flumazenil and its evaluation in cynomolgus monkey by positron emission tomography. Nucl Med Biol. 2005;32:109–116
  13. Odano I, Farde L, Karlsson P, Varrone A, Krasikova R, Airaksinen A, et al. [18F]Flumazenil for central benzodiazepine receptor imaging and its comparison with [11C] in human brain. J Nucl Med. 2007;48:61P
  14. Krasikova RN, Ryzhikov NN, Gomzina NA, Vassiliev DA, Kostikov AP, Fedorova OS. Isotopic 18F/19F exchange in the flumazenil molecule using K18F/Kryptofix complex. J Label Compd Radiopharm. 2003;46:S213
  15. Ryzhikov NN, Gomzina NA, Fedorova OS, Vasil’ev DA, Kostikov AP, Krasikova RN. Preparation of [18F]flumazenil, a potential radioligand for PET imaging of central benzodiazepine receptors by isotope exchange. Radiochemistry. 2004;46(3):290–294
  16. Gomzina NA, Zaitsev VV, Krasikova RN. Optimization of nucleophilic fluorination step in the synthesis of various compounds labeled with fluorine-18 for their use as PET radiotracers. J Label Compd Radiopharm. 2001;44:S895–S897
  17. Yamada R, Watanabe M, Omura T, Sato N, Shimizu K, Takahashi M, et al. Development of a small animal PET scanner using DOI detectors. IEEE Trans Nucl Sci. 2008;55(3):906–911
  18. Liu R. Water-insoluble drug formulation. 2nd ed. Florida: CRC Press; 2008;
  19. Goeders NE, Kuhar MJ. Benzodiazepine receptor binding in vivo with [3H]-Ro 15-1788. Life Sci. 1985;37:345–355

PII: S0969-8051(09)00038-9

doi: 10.1016/j.nucmedbio.2009.01.011

Nuclear Medicine and Biology
Volume 36, Issue 4 , Pages 403-409 , May 2009